email home
Products > PROMARINE®-450 > Applications > Fire Protection > Bulkhead Installation Instruction  
   
  B15 Standard Bulkhead

This instruction is based on the use of a B15 rated bulkhead, using 19mm thick PROMARINE®-450 and laminated on both sides with 0.8mm thick HPL (high pressure laminate)
 
 
Detail C
 C - spline joint
 
     
 
C-spline joints are used where a flush finish is required. Bonded panels are supplied with grooves cut into the long edges, together with the necessary C-splines (PJ-1-A).

It is recommended that the C-splines used are supplied by Promat in order to guarantee a correct fit. Starting at a corner, boards are simply pushed together as shown, ensuring that the flat side of the spline is facing the decorative side of the boards.
 
Bulkhead Profiles

PJ-1-A
(click here to see the details)

PJ-1-A

 


Detail C
 

 
   
 
  Detail A Detail B Detail C Detail D Detail E Detail F


 

 
 
 