email home
Products > PROMARINE®-450 > Applications > Fire Protection > Bulkhead Installation Instruction  
   
  B15 Standard Bulkhead

This instruction is based on the use of a B15 rated bulkhead, using 19mm thick PROMARINE®-450 and laminated on both sides with 0.8mm thick HPL (high pressure laminate)
 
 
Detail D
 Omega Joint
 
     
 
Omega joints are generally used in areas where boards may have to be removed from time to time. This method allows an individual board to be removed without disturbing an adjacent board. The Omegas should be trimmed to the required length and loosely screwed together using the screws supplied, and inserted between the boards as shown.

As with the C-spline above, starting at the corner, boards are pushed together into the Omegas, and the screws tightened until a tight fit is achieved.
 
 



Detail D
 

 
  Detail A  Detail B  Detail C  Detail D  Detail E Detail F  
 
 